OM2500 HF     Price no Tax ±: ? €                                                             updated jan 2016
F E A T U R E S
Frequency coverage, included Warc (MHz) 1.8 – 29.7 MHz including WARC
Power PeP HF (SSB/CW in W) - HF Rtty, digital mode, FM, - and VHF 2500W in SSB/CW, 2000 W CW/SSB/RTTY
Power Pep VHF (SSB/CW in W)
Power input (W) - Power out Low, Medim, High 40 to 60 W for full output power
Change band
Alc
Alphanumeric Display (W, A,band, T°, R.o.s. alarms, ect.) and/or Bar display and/or analog instrument Led bar graph indications: - Power output – bargraph 50 LED, reflected power,bargraph 20 LED
- Current at screen ( Ig2 – bar graph 10 LED )
- Anode voltage, anode current, tuning – bargraph 30 LED
Led Indicators:current at control grid ( Ig1 – 2 LED )
- WAIT – preheating of tube (180 sec )
- STBY– standby
- OPR – operating condition
- FAULT – failure, switching off for abt. 4 sec
- CAT (Icom, Yaesu, Kenwood, ect.)
- Power Tube type FU-728F Ceramic Tetrode
- Low pass filters
- Harmonic suppression (less..); Harmonic 3' Order Suppression min -50 dBc
- Remotely Controllabl
- Automatic Tuner, time, banda Ros
- Insertion loss with/out ATU
- TX SO-239/RX SO-239 1
- Interface (I/O, …)
- Cooling fans(dBmax) Centrifugal blower + axial blower
- Power supply 220, 230 , 240 V – 50/60 Hz
- Type circuit power supply; Maximium Power Transformers: 2 pcs of toroidal transformer 2kVA
Compliance; preparing different market
Kit (Cables. bag, Software...)
Warranty
Size (WxHxD,cm) 486 x 200 x 455 mm [19.1” x 7.9” x 17.9”]
Weight (kg) 38kg
Microprocessor controll
Availability Accessories
Opzional
Notes Protections:SWR too high
- Anode current too high
- Screen current too high
- Grid current too high
- Mistuning of power amplifier
- Soft start for protecting your fuses
- “switch –on blocking “ at opened amplifier
Marketing year beginning
Photos
Back to content