OM2500A - Hamradioguide

Go to content
Amplifiers ▪ Tubes ▪ HF
OM2500A       Price no Tax ±: ? €                                                              updated jan 2016
F E A T U R E S
Frequency coverage, included Warc (MHz) 1.8 – 29.7 MHz including WARC
Power PeP HF (SSB/CW in W) - HF Rtty, digital mode, FM, - and VHF 1500w PEP continuous output all modes – *no time limit*
Power Pep VHF (SSB/CW in W)
Power input (W) - Power out Low, Medim, High 40 to 60 W for full output power
Change band Automatic
Alc
Alphanumeric Display (W, A,band, T°, R.o.s. alarms, ect.) and/or Bar display and/or analog instrument Led bar graph indications: - Power output – bargraph 50 LED, reflected power,bargraph 20 LED
- Current at screen ( Ig2 – bar graph 10 LED )
- Anode voltage, anode current, tuning – bargraph 30 LED
Led Indicators:current at control grid ( Ig1 – 2 LED )
- WAIT – preheating of tube (180 sec )
- STBY– standby
- OPR – operating condition
- FAULT – failure, switching off for abt. 4 sec
- Inhibit – operating condition
- ANT 1 - which ANT is use
- ANT 2 – which ANT is use
- UP – DWN - listing in menu
- MAN - manual operating
- AUTO - automatic operating
- TUNE - tuning
- ANT - ANT selection
Power Tube type FU-728F Ceramic Tetrode
Low pass filters
Harmonic suppression (less..); Harmonic 3' Order Suppression < -52 dBc second, < -65 dBc third
Remotely Controllabl
Automatic Tuner, time, banda Ros
Insertion loss with/out ATU
TX SO-239/RX SO-239 Antenna switch for 2 antennas
Interface (I/O, …)
Cooling fans(dBmax) Centrifugal blower + axial blower
Power supply 220, 230 , 240 V – 50/60 Hz
Type circuit power supply; Maximium Power Transformers: 2 pcs of toroidal transformer 2kVA
Compliance; preparing different market
Kit (Cables. bag, Software...)
Warranty
Size (WxHxD,cm) 485 x 200 x 455 mm [19.1” x 7.9” x 17.9”]
Weight (kg) 41.5kg (92lb)
Microprocessor controll
Availability Accessories
Opzional
Notes Protections:SWR too high
- Anode current too high
- Screen current too high
- Grid current too high
- Mistuning of power amplifier
- Soft start for protecting your fuses
- “switch –on blocking “ at opened amplifier FCC Approuved
Marketing year beginning
Photos
Back to content